  • opti 6s 5000 normal cell resistance

    What sort of cell resistance are you all getting with your opti packs.
    I have 2 opti 6s 5000 I use in my 550 & tonight I've noticed a prety high
    internal resistance on cell 3 of 4.3 m ohm & the rest vary from 1.4 to 1.7 m ohm
    Pics attached. This is only on the one pack & it seems to be performing reasonably well should I worry
    or is this normal?
    Click image for larger version

Name:	IMG_0393[1].jpg
Views:	1
Size:	204.8 KB
ID:	1908032Click image for larger version

Name:	IMG_0394[1].jpg
Views:	1
Size:	194.9 KB
ID:	1908031
    Martin
    Aka RCSlopesurfer

  • #2
    on my powerlab 8 i all ways get one ir reading higher than the other but thats on turnigy's a guy aslo mentioned it at my field as well with his powerlab i think they brought out a update to fix it but i dont have the usb cable to update and see if it worked

    but i do think its just the powerlab not your packs ( i could be wrong tho so please correct me if i am )
    Tbs discovery quad
    Align 700L Dominator
    Gaui x3
    mikado logo 480 Xxtreme





    Comment


    • #3
      Im running the latest firmware though?
      Martin
      Aka RCSlopesurfer

      Comment


      • #4
        I think the incorrect Ir on the PL8 was shown on the last cell. If it's in the middle Martin I reckon it's correct. Although the IR readings on the PL8/6 have been shown to be a bit off. A couple of the guys are using a more accurate way of measuring it and this has shown chargers IR readings to be a bit suss
        Humble owner of 7 Eddie Gold Stars and Ex - member of Mk Heli Club
        sigpic

        Comment


        • #5
          Originally posted by rcslopesurfer View Post
          Im running the latest firmware though?
          Martin Are you using pitch Boost on vbar and rinsed out your pack!!!
          Santander Factory Team

          Proud wearer of 5 x EGS

          Comment


          • #6
            Originally posted by rcslopesurfer View Post
            Im running the latest firmware though?

            ohh i arnt sure then sorry about that i just thought it was a software bug as the another guy i know his powerlab was doing the same i will have check my lipos then and get it updated
            Tbs discovery quad
            Align 700L Dominator
            Gaui x3
            mikado logo 480 Xxtreme





            Comment


            • #7
              version v3.31
              Santander Factory Team

              Proud wearer of 5 x EGS

              Comment


              • #8
                ***VERSION 3.31 2-24-12*** Fixed MPA internal resistance reading.
                so the charger says
                Santander Factory Team

                Proud wearer of 5 x EGS

                Comment


                • #9
                  As Dave says, this was a problem affecting typically the last cell, and then only when using a balance board that needed XMA wiring mode.

                  If you see a cell in the middle that is significantly different then the odds are something is not right.

                  One thing though is do make sure the pack has a chance to settle at room temperature before testing. As an example if you were to hold the pack so you warmed up the outer cells in the pack then test you would find the middle cells had a higher resistance.

                  Just leave the pack in the room for a couple of hours then charge, if you are seeing the same then I'd talk to OptiPower as a difference that high will just result in the pack degrading over time.

                  Comment


                  • #10
                    Mine was reading exactly the same until I installed the latest 3.31 firmware Martin.

                    All is well now after updating.

                    Comment


                    • #11
                      We had a similar problem a few days ago that was cured by cleaning the balance connector. (Much to my annoyance as it shouldn't make that much difference, but it does in some cases). A cell with high ir will warm up quicker and its ir will drop. The other cells will act as a heatsink. Mark mentioned a thread about it. If it is a real effect then that cell will not last as long as the others. I would borrow a Wayne-Giles meter or use an I charger to check.

                      I doubt if it is a real problem, it is too big a difference. If it is real you are covered by the guarantee. You can get a rough estimate of ir by checking how the cell volts change as a current changes. If you start charging at 5 or 10 amps you will see a big change in cell volts. If your cell really has an ir 3 times more than the others then the change will be three times as big.

                      ir comes from change in voltage divided by change in current. A 1 milli ohm ir means a 1mv change for a 1 amp change. We should call it partial dv/dt with other parameters held constant. Calling it ohms is pretty close to the truth. So you should see a 10mv change in cell voltage when charge current is changed from 0.1 to 10.1 amps on a 1 millohm cell and 30mv change on a 30 milliohm cell. This time contact resistance shouldn't make a difference, unless the charger uses a lot of current to measure voltage.


                      It might be worth looking at the crimp on the cell that is giving a problem. It may not be pushed in far enough and held by the finger, or it may be gripping too much insulation. There may be a dirty pin on the connector.
                      Flasher 450 Sport. Assan GA250 with 520 tail servo, MKS DS450 cyclic.
                      Multiplex Cockpit Tx, DX7, DX6i
                      Blade 130-X, MSR, MSRX
                      Phoenix Sim

                      Comment


                      • #12
                        Hi Martin , not sure bout the update fixing things as I ain't done it yet , but you will get a higher ir reading on cell 3/4 because of the "joint" that opti and others put in ( between cell 3&4)to get round air travel limits on cells , as in when you go to say rc hotel etc
                        jeff

                        outrage velocity 50 fbl ,v-bar
                        logo 600 3d

                        mobile bar-b-q
                        a few planks and a big overdraft

                        Comment


                        • #13
                          Originally posted by spiderspid View Post
                          Hi Martin , not sure bout the update fixing things as I ain't done it yet , but you will get a higher ir reading on cell 3/4 because of the "joint" that opti and others put in ( between cell 3&4)to get round air travel limits on cells , as in when you go to say rc hotel etc
                          +1 on the above
                          Avant Aurora 90, ys powered
                          Avant Aurora Ys120 V bar
                          Rave Env Ys120 true power Beast X

                          pheonix sim
                          Dji s800

                          Comment


                          • #14
                            my 6s 5000s are reading 0.9 which i thought was pretty damn good. This is on my cellpro 10s, not sure how accurate the reading is though?
                            Avant mostro 700E
                            Avant mostro 700 Nitro



                            member of :
                            South cheshire heliaddicts

                            Comment


                            • #15
                              Originally posted by GIXERMAN View Post
                              Martin Are you using pitch Boost on vbar and rinsed out your pack!!!
                              No mate I don't use pitch pump on the vbar but the packs are being pushed hard lately on my 550